Skip to content
Lab Package: CX20 Insulated Lab and 10lb closed loop active extractor

Lab Package: CX20 Insulated Lab and 10lb closed loop active extractor

$80,000

Steel container C1D1 lab with process equipment.

QTY
☎  CALL 1-800-968-8461
  • Freight shipping nationwide — lead time quoted with your order
  • Engineer/peer reviewed design, built to ETL and UL 1389 standards
  • UL 508A controls · drawing package for your AHJ
✓NEC ARTICLE 500C1D1 Design✓NFPA 33Spray Application✓PEER REVIEWEDEngineer Reviewed✓UL 508AControls✓ETL / UL 1389Built to Standards

Details

10lb closed loop extractor includes

CX20 C1D1 outdoor lab

Installation: Installation of all the hardware is done at our factory, there may be some items that have to be mounted back on site because of road travel restrictions.

Construction: Constructed out of 14 Gauge Steel, which exceeds 1 Hour fire wall.

Exterior Paint: Marine grade epoxy primer paint, with a direct to metal marine grade top coat for protection of the elements.

LED Light Fixtures: explosion proof lights LED Fixtures in the C1D1 area. The LE551 Series is designed for environments having explosive atmospheres.

Man Door: man access door . fire-resistive Gray Right-Hand Flush Steel Prehung Commercial Door and Frame with Panic Bar and Hardware, third-party door hardware

Strobe Light Explosion proof: Class I Divisions 1 & 2 Explosion Proof LED Light with Emergency Battery Backup.

Flooring: High traffic grade linoleum flooring, This vinyl floor tile is ideal for use in commercial, residential, and institutional applications.

18″ Exhaust Fan with explosion proof motor -Exhaust Fan: One (1) 18″, 6-blade Acme exhaust fan used to pull gas from the C1D1 booth.

Control Panel: CM200 Control Panel Nema 4 enclosure (1) VFD sized for booth motors, Main disconnect of 40A with lock out tag out handle On/off light switch for booth lights On/off switch for fans E-stop button Light indicator on panel Make up and Exhaust Run lights Make up fault light Exhaust fault light Warning beacon on top of enclosure.

LEL Gas Detector: Stand Alone Explosion Proof Transmitter C1D1 Features Operates with or without a controller.

Audible and Visual Alarms: LED Blinking light element 24VAC/DC RD, Terminal element BWM 12-230VAC/DC BK, Buzzer element contin/pulse 24VAC/DC BK. UL Type classification Type 12.

Exit Signs: Glow-in-the-dark exit signs are critical in guiding employees and visitors out of your facility in an emergency.

Fire Suppression: Dry Chemical Suppression system installed. Activation and permit. Permit and activation locally by a fire contractor required

Motorized Damper: Extruded Aluminum, Number of Panels 1, 100 to 240 Voltage: This Dayton® power-open/spring-return, single-panel motorized channel-style damper regulates exhaust or supplies airflow in medium- and low-pressure commercial applications

Explosion Proof Outlet: The EPO-20A ensures secure electrical connections in Class I Division 1.

Electrical Panel: 125 Amp electrical panel with 2 breakers 125 A Amps, 120/240V AC, QO Circuit Breaker Type. Molded Case Circuit Breaker, 125 A, 240V AC, 2 Pole, Free Standing Mounting Style, QB Series.

10Lb Closed Loop extraction system

TRU-10lb System

manufacturer-marked 21CFM UVP-21 Corrosion Resistant 2-Stage Vacuum Pump

30L 200°C 6KW or 3KW Closed Loop Heater CRH-30L (included in passive system)

40ºC 50L Closed Loop Recirculating Chiller CLC-50/40 (included in passive system)

Master Vapor Pump 6CFM Recovery Pump (Included in Active System)

Order yours with a HD fisheye camera for more.